Two chlorine sensor measuring precept

Residual chlorine sensors are based mostly on different measuring principles, could be divided into diaphragm polarographic sensor and constant voltage sensor.
Used for steady monitoring of residual chlorine.
เพรสเชอร์เกจ , cathode, anode, electrolyte and cathode coated with a layer of gas permeable skinny movie composition. The remaining chlorine within the tested answer diffuses to the cathode by way of the diaphragm, and the cathode and anode are appropriate the polarization voltage can reduce the residual chlorine on the cathode, and these chemical reactions occur in the residual chlorine in the measured answer chlorine is proportional to the current.
fixed voltage sensor, composed of two platinum electrodes and a reference electrode to form a microbattery measurement system. During measurement, a stable electrical potential is maintained on the measuring end of the electrode, and completely different elements are produced under this electrical potential generate totally different, properly linear present intensities.
polarographic sensor is characterised by:
Sensitive reaction, excessive accuracy, good stability

Simple operation and small maintenance

Suitable for all kinds of media, movie is not easy to break, air pollution resistance

constant voltage type sensor is characterised by:
With steady zero efficiency, to make sure accurate and reliable measurement

Simple construction, easy to clean

It is appropriate for measuring residual chlorine, chlorine dioxide and ozone in water

Correction:
Zero point correction

Zero correction with chlorine-free water

Slope correction

Actual measurements are made in a portable or laboratory setting

Make alignment

Matters needing attention:
PH should be controlled at 5-8pH

The circulate must be controlled at 60-80L/H

The strain is within 4bar

Read more about water high quality:
Turbidity meter working principle

Main water high quality indicators

COD VS BOD

What is salinity meter?
You should weigh every one of the various choices introduced to you when you consider #keyword#. Analyze the problem and research the information introduced. After that, modify it to suit your personality and favorite means of doing things. Are ไดอะแฟรม ซีล who takes plenty of time to pay attention to your gut instincts, often called intuition? Doing this is among the best approaches to come to suitable decisions when considering these subjects as #keyword#. It in no way hurts to collect details and discover as many handy strategies as possible, so you might desire to visit #links# and observe exactly what they should state.


Residual chlorine sensors are primarily based on totally different measuring ideas, can be divided into diaphragm polarographic sensor and fixed voltage sensor.
Used for steady monitoring of residual chlorine.
diaphragm polarographic sensor, cathode, anode, electrolyte and cathode coated with a layer of gasoline permeable skinny movie composition. The remaining chlorine in the tested resolution diffuses to the cathode by way of the diaphragm, and the cathode and anode are applicable the polarization voltage can reduce the residual chlorine at the cathode, and these chemical reactions happen in the residual chlorine in the measured solution chlorine is proportional to the present.
fixed voltage sensor, composed of two platinum electrodes and a reference electrode to type a microbattery measurement system. During measurement, a secure electrical potential is maintained on the measuring finish of the electrode, and totally different parts are produced underneath this electrical potential generate completely different, well linear present intensities.
polarographic sensor is characterized by:
Sensitive response, excessive accuracy, good stability

Simple operation and small maintenance

Suitable for all kinds of media, movie just isn’t straightforward to damage, air pollution resistance

fixed voltage sort sensor is characterized by:
With stable zero performance, to make sure accurate and reliable measurement

Simple construction, straightforward to scrub

It is suitable for measuring residual chlorine, chlorine dioxide and ozone in water

Correction:
Zero point correction

Zero correction with chlorine-free water

Slope correction

Actual measurements are made in a conveyable or laboratory setting

Make alignment

Matters needing attention:
PH ought to be controlled at 5-8pH

The move must be managed at 60-80L/H

The stress is inside 4bar